Simulation of human respiration in fMRI with a mechanical model

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

Formats Non-Member Member
$31 $13
Learn how you can qualify for the best price for this item!
Become an IEEE Member or Subscribe to
IEEE Xplore for exclusive pricing!
close button

puzzle piece

IEEE membership options for an individual and IEEE Xplore subscriptions for an organization offer the most affordable access to essential journal articles, conference papers, standards, eBooks, and eLearning courses.

Learn more about:

IEEE membership

IEEE Xplore subscriptions

4 Author(s)
Brosch, J.R. ; Dept. of Biomed. Eng., Purdue Univ., West Lafayette, IN, USA ; Talavage, Thomas M. ; Ulmer, J.L. ; Nyenhuis, John A.

Obtaining functional magnetic resonance images of the brain is a challenging measurement process having a low characteristic signal-to-noise ratio. Images contain various forms of noise, including those induced by physiologic processes. One of the prevalent disturbances is hypothesized to result from susceptibility fluctuations caused by abdominal volume changes during respiration. To test this hypothesis and characterize the contribution of respiration noise to both magnitude and phase images, a mechanical model of a respiring human was constructed. The model was tested by comparing data from the model with that of a resting human. Power spectrum analyses show that the model induces both phase and magnitude disturbances similar to those in the human. The disturbances are directly related to the frequency of the respiration, with the noise most prevalent in the phase images. Though magnitude image noise is hard to identify in the human, the manikin demonstrates the presence of this disturbance. The construction of the manikin rules out motion as the primary source of the observed fluctuations and variation of the electrical properties of the manikin also indicates that signal fluctuations are not primarily due to eddy currents. Therefore, the changes are most probably induced by bulk susceptibility changes correlating with respiration.

Published in:
Biomedical Engineering, IEEE Transactions on  (Volume:49 ,  Issue: 7 )

Date of Publication: July 2002

Need Help?


IEEE Advancing Technology for Humanity About IEEE Xplore | Contact | Help | Terms of Use | Nondiscrimination Policy | Site Map | Privacy & Opting Out of Cookies

A not-for-profit organization, IEEE is the world's largest professional association for the advancement of technology.
© Copyright 2013 IEEE - All rights reserved. Use of this web site signifies your agreement to the terms and conditions.