Evaluation of rotating slant-hole SPECT mammography using Monte-Carlo simulation methods

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

Formats Non-Member Member
$31 $13
Learn how you can qualify for the best price for this item!
Become an IEEE Member or Subscribe to
IEEE Xplore for exclusive pricing!
close button

puzzle piece

IEEE membership options for an individual and IEEE Xplore subscriptions for an organization offer the most affordable access to essential journal articles, conference papers, standards, eBooks, and eLearning courses.

Learn more about:

IEEE membership

IEEE Xplore subscriptions

5 Author(s)
Baird, W.H. ; Dept. of Biomed. Eng., North Carolina Univ., Chapel Hill, NC, USA ; Frey, E.C. ; Tsui, B.M.W. ; Yuchuan Wang
more authors

Multi-segment slant-hole (MSSH) collimators provide much higher detection efficiency of breast lesions at a single view than conventional low-energy high-resolution (LEHR) parallel-hole collimators. The purpose of this study is to evaluate rotating MSSH (RMSSH) SPECT mammography using Monte Carlo Simulation methods. We modified the SIMIND Monte Carlo code to generate RMSSH projection data including the effects of attenuation, collimator-detector response and scatter from a realistic NCAT phantom with an attached breast and a lesion placed at locations at the center and at the near and far walls of the breast. The projection data were reconstructed using analytic and iterative image reconstruction methods. For comparison, we examine an LEHR collimator with a resolution of 1 cm at 15.2 cm, which is the same as that of the MSSH at the center of the common volume-of-view. Also, we simulated the inclusion of a lead shield that covers the body to keep photons emitted from the other organs from reaching the MSSH collimator. Our results indicated that RMSSH SPECT provides greater breast lesion contrast than that of a planar image taken using a conventional LEHR collimator at all lesion locations. Depending on the lesion location, the spatial resolution of the RMSSH SPECT images may be comparable or slightly poorer than that of the planar scintimammographic images obtained using a LEHR collimator. Shielding of photon emissions from the other organs substantially improves the RMSSH SPECT image quality. We conclude that the Monte Carlo simulation methods are useful in evaluating the application of RMSSH SPECT to breast imaging as compared to conventional planar scintimammography and that RMSSH SPECT may enhance lesion detectability.

Published in:

Nuclear Science Symposium Conference Record, 2001 IEEE  (Volume:3 )

Date of Conference:

4-10 Nov. 2001