Gottschalk, J.R. ; Dept. of Phys. & Astron., Toledo Univ., OH, USA ; Shvydky, O. ; Compaan, A.D. ; Theodosiou, Constantine E.
more authors

We have used a commercially available monochrome plasma display panel (PDP) to study the electrical and optical properties of PDPs. The monochrome PDP was filled with helium at a pressure of 0.5 atm with the visible light emission observed directly from the gas discharge. The PDP is driven by an AC voltage source, operating at ~130 V at 50 kHz. With nanosecond resolution we have measured the current in the panel and the spectrally resolved light emission from the panel as a function of applied voltage. This study of a helium-filled conventional PDP is designed to provide data needed for improved modeling calculations of the plasma discharge. The ultimate goal is to achieve improved designs and efficacies for large-screen color PDP's

Published in:

Plasma Science, IEEE Transactions on  (Volume:27 ,  Issue: 3 )