Goals for the design of electrical systems that include both linear and nonlinear loads are established in this standard. The voltage and current waveforms that may exist...Show MoreScope:This standard establishes goals for the design of electrical systems that include both linear and nonlinear loads. The voltage and current waveforms that may exist throug...Show More
Purpose:This standard is to be used for guidance in the design of power systems with nonlinear loads. The limits set are for steady state operating conditions. In any case, the l...Show More
Metadata
Abstract:
Goals for the design of electrical systems that include both linear and nonlinear loads are established in this standard. The voltage and current waveforms that may exist throughout the system are described, and waveform distortion goals for the system designer are established. The interface between sources and loads is described as the point of common coupling and observance of the design goals will reduce interference between electrical equipment. This standard addresses steady-state limitations. Transient conditions exceeding these limitations may be encountered. This document sets the quality of power that is to be provided at the point of common couplin...
Scope:
This standard establishes goals for the design of electrical systems that include both linear and nonlinear loads. The voltage and current waveforms that may exist throughout the system are described, and waveform distortion goals for the system designer are established. The interface between sources and loads is described as the point of common coupling and observance of the design goals will reduce interference between electrical equipment. The voltage and current distortion limits in this standard shall apply at the user point of common coupling (PCC) to overall installation containing harmonic producing loads (nonlinear equipment). Users are directed to ...
Purpose:
This standard is to be used for guidance in the design of power systems with nonlinear loads. The limits set are for steady state operating conditions. In any case, the limit values given in this document should not be considered binding in all cases. Some conservatism is present that may not be necessary in all cases. This standard shall be applied at a PCC between system owners or operators and users in the power system. The limits in this standard are intended for application at a PCC between the system owner or operator and a user, where the PCC is usually taken as the point in the power system closest to the user where the system owner or operator could...
Date of Publication: 05 August 2022
Electronic ISBN:978-1-5044-8727-6
ICS Code: 27.100 29.240.01 - Power stations in general Power transmission and distribution networks in general