Abstract:
The performance of transformers in the presence of oscillatory transients is addressed in this guide. Oscillatory transients are typically produced by the interaction of ...Show MoreScope:This Guide addresses the application of transformers in the presence of oscillatory switching transients. These oscillatory transients are typically produced by the inter...Show More
Purpose:When a transformer is switched into or out of a system, the transient voltage produced at the terminals of the transformer may contain several high frequency oscillatory ...Show More
Metadata
Abstract:
The performance of transformers in the presence of oscillatory transients is addressed in this guide. Oscillatory transients are typically produced by the interaction of the switching device, transformer, load, and system. This guide describes operating conditions that may produce oscillatory switching transient voltages damaging to the transformer insulation system. It discusses the electrical characteristics of the source, switching device, transformer, load, and the nature of their transient interaction. It discusses several mitigation methods. Two generic examples are included. This guide focuses on mechanical switching devices and does not address semic...
Scope:
This Guide addresses the application of transformers in the presence of oscillatory switching transients. These oscillatory transients are typically produced by the interaction of the switching device, transformer, load, and system. This Guide defines operating conditions that may produce switching voltages damaging to the transformer insulation system. It discusses the electrical characteristics of the system source, switching device, transformer, and load and the nature of their transient interaction. It outlines several mitigation methods. Two examples are included. This Guide recognizes that many devices and/or system operations can produce oscillatory t...
Purpose:
When a transformer is switched into or out of a system, the transient voltage produced at the terminals of the transformer may contain several high frequency oscillatory components. When this oscillatory transformer terminal voltage has a frequency component near one of the natural frequencies of the transformer and is of sufficient magnitude and duration, permanent damage to the transformer internal insulation structure may result. The purpose of this Guide is to provide aid in the recognition of conditions and applications where transformers are subjected to terminal oscillatory switching transients that may produce internal winding voltages damaging to th...
Date of Publication: 23 March 2022
Electronic ISBN:978-1-5044-8555-5
ICS Code: 29.180 - Transformers. Reactors
Persistent Link: https://ieeexplore.ieee.org/servlet/opac?punumber=9741449