62271-111-2005 - IEC 62271-111 Ed.1 (IEEE Std C37.60-2003-Compilation): High Voltage Switchgear and Controlgear — Part 111: Overhead, Pad-Mounted, Dry Vault, and Submersible Automatic Circuit Reclosers and Fault Interrupters for alternating current systems up to 38 kV | IEEE Standard | IEEE Xplore

62271-111-2005 - IEC 62271-111 Ed.1 (IEEE Std C37.60-2003-Compilation): High Voltage Switchgear and Controlgear — Part 111: Overhead, Pad-Mounted, Dry Vault, and Submersible Automatic Circuit Reclosers and Fault Interrupters for alternating current systems up to 38 kV


Abstract:

This Standard applies to all overhead, pad mounted, dry vault and submersible single or multi-pole alternating current automatic circuit reclosers and fault interrupters ...Show More
Scope:This Standard applies to all overhead, pad mounted, dry vault and submersible single or multi-pole alternating current automatic circuit reclosers and fault interrupters ...Show More
Purpose:The purpose of this project is to revise existing standard including, but not limited to: a) general update to bring the standard in line with current technology; b) upda...Show More

Abstract:

This Standard applies to all overhead, pad mounted, dry vault and submersible single or multi-pole alternating current automatic circuit reclosers and fault interrupters for rated maximum voltages above 1000 V and up to 38 kV. The following is also included in section 1: In order to simplify this standard where possible, the term recloser/FI (reclosers/FIs) has been substituted for automatic circuit recloser or fault interrupter or both. NOTE--When reclosers are applied in substation, special considerations may apply.
Scope:
This Standard applies to all overhead, pad mounted, dry vault and submersible single or multi-pole alternating current automatic circuit reclosers and fault interrupters for rated maximum voltages above 1000 V and up to 38 kV. The following is also included in section 1: In order to simplify this standard where possible, the term recloser/FI (reclosers/FIs) has been substituted for automatic circuit recloser or fault interrupter or both. NOTE--When reclosers are applied in substation, special considerations may apply.
Purpose:
The purpose of this project is to revise existing standard including, but not limited to: a) general update to bring the standard in line with current technology; b) update information on BIL, altitude correction, temperature rise; c) add information on other interrupting/insulating media (e.g. SF6); d) add transient recovery voltage requirements; e) add voltage ratings common to systems outside of North America
Date of Publication: 12 July 2006
Electronic ISBN:978-2-8318-8378-6
Persistent Link: https://ieeexplore.ieee.org/servlet/opac?punumber=11022