Magnetic Priming of a Relativistic Magnetron by Ferromagnetic Wires in the Anode and Cathode*
Gilgenbach, R.M.; Hoff, B.W.; Lau, Y.Y.; Jordan, N.M.; White, W.; Zier, J.C.; Gomez, M.R.; Cruz, E.; Spencer, T.A.; Price, D.
Vacuum Electronics Conference, 2007. IVEC apos;07. IEEE International
Volume , Issue , 15-17 May 2007 Page(s):1 - 2
Digital Object Identifier 10.1109/IVELEC.2007.4283397
Summary:Magnetic priming consists of N/2 azimuthal perturbations applied to the axial magnetic field in an N-cavity magnetron. When employed on the UM/L-3-Titan, 6-cavity, relativistic magnetron (L-band, -300 kV, ~3 kGauss), magnetic priming has shown enhanced performance over uniform-B- field operation. Magnetic perturbations are imposed utilizing Mu-metal wires embedded in either the cathode or both the cathode and anode of the magnetron.